18
Vent Con gurations
10’
15’
20’
25’
30’
35’
40’
4’6”
5’0”
5’6”
6’0”
6’6”
7’0”
7’6”
8’0”
9’0”
10’0”
8’6”
9’6”
3” Liners
3” min. Bend
Radius
Vertical Vent Height
Allowable Horizontal Offset
10’ min. - 40‘ max.
559CLT
Co-Linear Terminal
See
Chart
559CLT
Termination
3” Inlet & Exhaust
Collars (exhaust collar
is slighthly longer)
10”
10”
Allowable Vent Con gurations
The RF24 is certi ed for use with approved 3” diameter
exible venting installed into an approved existing solid
fuel burning masonry or factory built chimney system.
The venting system must terminate vertically at the
roof using an approved termination cap. Both inlet and
exhaust liners must be run continuously from appliance
to roof termination.
Where possible, avoid joints in ex pipe. If joints
are required, use only connectors approved by the
manufacturer of the ex pipe. Field fabricated joints
are not allowed.
Any generic 3” diameter exible venting approved
for venting gas appliances is acceptable. See list of
the approved venting components on page 32 of this
manual.
WARNING
Failure to position the parts in
accordance with these diagrams or
failure to use only parts speci cally
approved with this appliance
may result in property damage or
personal injury.
!