Valor 737AN User Manual

Browse online or download User Manual for Water heaters & boilers Valor 737AN. installation and owner guide

  • Download
  • Add to my manuals
  • Print
  • Page
    / 56
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
5117209/03
© Baxi Heating U.K. Limited 2008.
Model 761
Inset live fuel effect gas fire
Incorporating the Valor Fires CONTROL
Fitted with one of the following fascia
Homeflame Dream or
Homeflame Harmony.
(G.C. Number 32-264-05)
INSTALLER: Please leave this guide with the owner
INSTALLATION AND OWNER GUIDE
We trust that this guide gives
sufficient details to enable this
appliance to be installed and
maintained satisfactorily. However, if
further information is required, our
Valor Fires Technical Helpline will
be pleased to help.
Telephone 0844 8711 565 (National
call rates apply in the United
Kingdom).
In the Republic of Ireland
Telephone 0044 844 8711 565.
Page view 0
1 2 3 4 5 6 ... 55 56

Summary of Contents

Page 1 - Homeflame Harmony

5117209/03© Baxi Heating U.K. Limited 2008.Model 761Inset live fuel effect gas fireIncorporating the Valor Fires CONTROLFitted with one of the follow

Page 2

4.2.1.1 ‘Hole-in-the-wall’ Installations It is recommended that a hearth should be installed as in section 4.9.  Homeflame Dream firefront If a red

Page 3

heat transfer may cause crackingon directly plastered flues.However, generally this applianceis suitable for installations under allcircumstances unle

Page 4

accordance with BS 5440: Part 1 Annex A, the minimum equivalent height of the flueshall be 2.0m of 125mm dia. flue pipe.4.5 The flue must not be used

Page 5

4.14 Normal adventitious ventilation is usually sufficient to satisfy the ventilationrequirements of this appliance. In GB reference should be made t

Page 6

4.17 The appliance is fitted with an A.S.D (Atmosphere sensing device). If theappliance closes down after a period of operation for no apparent reason

Page 7

© Baxi Heating U.K. Limited 2008.Page 15Figure 5. Appliance dimensions and clearances (The fascia may differ from thatshown and dimensions are subject

Page 8

5. PACK CONTENTSThe items required for this appliance are packed in sections.Section 1 - Fire unit contains:1 Burner and convection box unit.1 Burner

Page 9

© Baxi Heating U.K. Limited 2008.Page 17Figure 6. Pack contents (Items are not to scale)INSTALLER GUIDE

Page 10 - INSTALLER GUIDE

6. FIREPLACE CHECK6.1 Fireplace check.6.1.1 Fireplace size.The fireplace must complywith the requirementsdescribed in section 4.2.This will probably e

Page 11

have deteriorated due to prolonged use, they should be made sound with suitablecement.6.1.4 Installations using a metal flue boxThe top, sides and rea

Page 12

© Baxi Heating U.K. Limited 2008.All rights reserved. No part of this publication may be reproduced in any material form(including photocopying), stor

Page 13

8. GAS SUPPLY CONNECTIONA nut and olive are provided for an 8mm pipe inlet connection to the ‘T’ connector atthe bottom front of the appliance. The ‘T

Page 14

3. Lift the glass panel clear of itslower support channels (See figure11). Lower and remove the glasspanel. Place the glass panel in a safeplace away

Page 15

8. The appliance is supplied with two firebackspacers that must be fitted in all installations. Theseshould extend backwards to ensure sufficient clea

Page 16

10. There is a length of self adhesive foam sealsupplied with the fire. This will need to be fitted tothe outer rear edges of the side and top flanges

Page 17

10. CONVECTION BOX INSTALLATION10.1 Method 1 - Front fixing to fireplace surround.1. Make sure that the fireplace front surround area issound enough t

Page 18

into the plugs. Make sure that the bolts are secure.4. Place the convection box unit close to the fireplacebut allow sufficient access into the firepl

Page 19

11. Pull each cable taut. Push the cable retainershard up against the back panel. The end of thecable adjuster will pass into the hole. Tighten thescr

Page 20

11. BURNER AND SUPPLY PIPE INSTALLATION11.1 Burner and supply pipe installation.1. Remove the ‘Aeration checking’ reminder label from the top of the b

Page 21

11.3 Inlet pressure check.The appliance is pre-set to give the correct heatinput at the inlet pressure shown in section 3 ofthis manual. No adjustment

Page 22

13. FITTING THE GLASS PANELNote: When fitting the glass panel care mustbe taken to ensure that the bottom ofthe glass is lifted high enough to clearth

Page 23

Safety First.Valor Fires fires are CE Approved and designed to meet the appropriate BritishStandards and Safety Marks.Quality and Excellence.All Valor

Page 24

14. FULL OPERATING CHECKS14.1 Checking the control settings.Please note: When first turned on from cold, the flames will appear predominantly blue.

Page 25

If the smoke is not drawninto the appliance leavethe appliance alight at themaximum setting for afurther ten minutes andthen repeat the test. If thesm

Page 26

15. OUTLET BAFFLE AND FASCIA FITTINGHomeflame Dream model.15.1 Fitting the outlet baffle.Locate the outlet baffle and secure in placeusing two tapping

Page 27

centrally on top of the hearth in front of the fascia.Place the bottom front cover casting / ash pan inposition.Homeflame Harmony model.15.4. Fitting

Page 28

16. FINAL REVIEW1. COMPLETE THE INFORMATION IN THE WARRANTY AND SERVICE SECTIONOF THE OWNER GUIDE (See last pages of the OWNER guide).2. Visually insp

Page 29

17. SERVICING & PARTS REPLACEMENT Always turn off the gas supply before commencing any servicing and allowto cool completely. (The appliance inl

Page 30

17.2 To remove the ignition microswitch.See figure 35.The ignition microswitch is stampedV4NT9C4YC1. Remove the bottom front cover and thefire front c

Page 31

upper retaining brackets. See section 15 of this guide for detailed fitting instructions.Homeflame Harmony model.1. Carefully lift the fascia upward a

Page 32

17.7 To remove the glass panel.Note: When removing and fitting the glass panel care must be taken to ensure thatthe bottom of the glass is lifted high

Page 33

17.10 To remove the electronic ignition generator.1. Remove the bottom front cover, fire frontcastings, the fascia, glass panel and fuel effect asin s

Page 34

© Baxi Heating U.K. Limited 2008.Page 4INSTALLER GUIDEINSTALLER GUIDEFOR OWNER GUIDE SEE PAGES 43 TO 55

Page 35

17.12 To remove the thermocouple interrupter block.(See figure 36).1. Remove the burner unit (See section 17.11).2. Detach the thermocouple from the i

Page 36

7. Loosen the hexagonal locknut securingthe elbow to the tap. Remove the elbow byrotating it.8. If fitting a new tap, remove the hexagonalnut at the m

Page 37

17.16 To replace the burner. (See figure 47).1. Remove the burner unit (See section 17.11).2. Support the elbow injector and unscrew theinjector nut.3

Page 38

© Baxi Heating U.K. Limited 2008.Page 43OWNER GUIDEFOR WARRANTY AND SERVICE INFORMATIONSEE PAGES 52 TO 55OWNER GUIDE

Page 39

LIST OF CONTENTSSection PageSAFETY 45APPLIANCE DIMENSIONS 47GAS CONSUMPTION 48OPERATING YOUR FIRE 48The Oxysafe flame sensing and flue blockage saf

Page 40

SAFETYDo have the fire installed by a competent person. In the United Kingdom, installationmust be in accordance with the latest edition of the Gas Sa

Page 41

Do provide a suitable guard that complies with BS 8423 for the protection of youngchildren, the elderly and the infirm. Such a guard is also recommend

Page 42

APPLIANCE DIMENSIONS© Baxi Heating U.K. Limited 2008.Page 47OWNER GUIDEKey DescriptionModelHomeflameDreamHomeflameHarmonyA Height (mm) 636 631B Width

Page 43 - OWNER GUIDE

GAS CONSUMPTIONModel 761Has a maximum natural gas input of 5.0kW (Gross)Has a maximum natural gas output of 4.0kW Has a minimum natural gas input of 2

Page 44

the ‘Maintenance’ section of this guide.Until you can obtain a replacement battery the fire can be lit with a taper as describedlater in this guide.2

Page 45

CONTENTSSection Heading PageINSTALLER GUIDE 4 - 42OWNER GUIDE 43 - 551. SAFETY 62. ACCESSORIES 63. APPLIANCE DATA 74. GENERAL INSTALLATION REQUIREM

Page 46

Lighting with a taper.Important: When lighting with a match or taper be very careful not to placenaked flames by the plastic / rubber coated leads.Hom

Page 47

CLEANING YOUR FIRETo maintain the high performance and quality finish of your fire please follow theseguidelines:Before attempting to clean the fire,

Page 48

Regular maintenance.In order to achieve and maintain high levels of personal safety and performanceefficiency, it is essential that the opening at the

Page 49

What you need to do if you experience a problem with the operation of the fire:  You should always contact your installer first, because the cause o

Page 50

© Baxi Heating U.K. Limited 2008.Page 54OWNER GUIDEInstaller Details (Block Capitals)Installer NameCorgi Registration Number.Company Name.Company Addr

Page 51

© Baxi Heating U.K. Limited 2008.Page 55OWNER GUIDEFigure 6. Information labellocation.Brand (Please tick)Baxi Valor Wonderfire Other...

Page 52

© Baxi Heating U.K. Limited 2008.

Page 53

1. SAFETYInstallerBefore continuing any further with the installation of this appliance please read thefollowing guide to manual handling The lifting

Page 54

3. APPLIANCE DATAUnder no circumstances is this fire to be converted to LPG. An LPG conversion kitdoes not exist for this gas fire.The appliance infor

Page 55

This product uses fuel effect pieces and burner compartment walls containingRefractory Ceramic Fibres (RCF), which are man-made vitreous silicate fibr

Page 56

BS 8303 Parts 1,2 & 3 In England and Wales, the current edition of the Building Regulations issued by theDepartment of the Environment and the Wel

Comments to this Manuals

No comments