Valor 555CFK Operations Instructions

Browse online or download Operations Instructions for Household fans Valor 555CFK. Valor 555CFK Operating instructions User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 42
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
MADRONA
©2011, Miles Industries Ltd.
Madrona Free Standing Direct-Vent
Top or Rear Vent Stove
MF28ILN (NG) / MF28ILP (LPG)
Engine to be installed ONLY with the cast stove body
MFCS01 or MFCS02
4001917-06
WARNING: If the information in these
instructions is not followed exactly, a re
or explosion may result causing property
damage, personal injury or loss of life.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light the appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from
a neighbors phone. Follow the gas
suppliers instructions.
• If you cannot reach your gas supplier, call
the re department.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certi ed kit is used.
This appliance is a domestic room-heating
appliance. It must not be used for any other
purposes such as drying clothes, etc.
This appliance is suitable for installation in a
bedroom or bed sitting room.
Manufactured by
MILES INDUSTRIES LTD., British Columbia, Canada
www.valor replaces.com
Installation & Operating Instructions
Do not store or use gasoline or other
ammable vapors and liquids in the vicinity
of this or any other appliance.
Installation and service must be performed
by a quali ed installer, service agency or the
gas supplier.
This appliance may be installed in an
after-market permanently located,
manufactured (mobile) home where not
prohibited by local codes.
INSTALLER: Leave this manual
with the appliance.
CONSUMER: Retain this manual
for future reference.
Massachusetts: The piping and nal
gas connection must be performed by a
licensed plumber or gas tter in the State of
Massachusetts. Also, see Carbon Monoxide
Detector requirements under “Safety and
Warning Information” on page 5.
Please read this manual BEFORE
installing and operating this
appliance.
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
Page view 0
1 2 3 4 5 6 ... 41 42

Summary of Contents

Page 1 - MF28ILN (NG) / MF28ILP (LPG)

MADRONA©2011, Miles Industries Ltd.Madrona Free Standing Direct-Vent Top or Rear Vent StoveMF28ILN (NG) / MF28ILP (LPG)Engine to be installed ONLY wit

Page 2 - 36” (0.9 m)

10VentingTop / Rear OutletVent MaterialThis unit is shipped with a top outlet collar which is fi eld-convertible to rear outlet—see page 20 for details

Page 3 - Table of Contents

11Snorkel required (min. 14” high) with horizontal run through the wall(no rise)VentingThrough wall (without vertical rise)Typical Venting ComponentsS

Page 4

5 x 90º ELBOWS MAXIMUMRestrictor 75NORESTRICTORSExample 1NO INSTALLATIONNO INSTALLATIONV3Restrictor 502 4 6 8 10 12 14 16 18 2012VentingAllowable Vent

Page 5

13VentingRestrictorsSOME INSTALLATIONS REQUIRE RESTRICTORS. For improved fl ame picture and performance, this unit is supplied with two different sets

Page 6 - Massachusetts

14VentingKEY VENT TERMINAL LOCATIONS - MINIMUM DISTANCES MINIMUM CLEARANCE Inches CmA Clearance above grade, verandah, porch, deck or balcony 12 30B

Page 7 - Specifi cations

15Installation PlanningFan (Blower)Venting Confi gurationGas Line RoutingConsider visibility of shut-off valve or step-down regulators, etc. when plann

Page 8 - Dimensions & Clearances

16Appliance Preparation1. Rough-in the gas line and electrical wiring for a fan (if any).2. Decide where the stove should be positioned to avoid mov

Page 9

17Appliance PreparationEngine DetailFlip the base upside-down. Place the engine on the base at its approximate fi nal position—see detail below. Center

Page 10 - Vapor Barriers

18Appliance PreparationFit the pipe and connector supplied with the engine to the valve. Connect the gas line to the inlet pipe.3/8” gas line connecti

Page 11 - Components

19Appliance PreparationFasten Thermal Switch to underside of burner module using 2 existing screwsOptional Fan (Blower)If the Circulating Fan Kit (blo

Page 12 - Restrictor 75

2The information contained in this installation manual is believed to be correct at the time of printing. Miles Industries Ltd. reserves the right to

Page 13 - Restrictor 50 Restrictor 75

20Appliance PreparationTop Spar1. Position the top spar on the side brackets located between the engine and the cast sides.2. Fix the spar with four

Page 14 - Termination

21ConnectorPipesUnionsSupply Line SizeSealantManual Shut-off Valve & UnionTest Pressures >1/2 psig (3.5kPa)Possible DamagesTest Pressures ≤1/2

Page 15 - Installation Planning

Both front logs to rest slightly on the edge of the fi rebox window frame.1. Place the rear log centering it side to side in the fi rebox. Position for

Page 16 - Appliance Preparation

4. Identify the right cross log; it has a hole under on of its end and it is the shortest cross log. Place it on the right pin located on the rear lo

Page 17

24Window Refi ttingx 4To refi t the window, place it on the fi rebox frame and hold it in place while pushing and turning its fastening studs 90 degrees.

Page 18

25Front & Top InstallationFront InstallationHook the cast front to the side brackets located between the engine and the cast sides.Cast frontHookD

Page 19

26Top CastingPlace the top casting piece on the top of the stove ensuring the rear edge is fl ush with the rear edge of the cast side panels. Fill in t

Page 20

27For your safety, this appliance is fi tted with a fl ame supervision device which will shut-off the gas supply if, for any reason, the pilot fl ame goe

Page 21 - Supply Gas Installation

28BatteriesOwner’s InformationInspect the vent terminal outdoors regularly to make sure that snow, trees, bushes, leaves, or other objects do not obst

Page 22 - Ceramic Logs Installation

29Remote Control OperationYour fi replace remote control helps you get the comfort, convenience and aesthetics you want from your gas fi replace. The re

Page 23

3Table of ContentsSafety & Warning Information ...4Specifi cations ...

Page 24 - Remote Control Initial Set-up

30TimeThe flame height can be adjusted in the following manners. In STANDBY mode,1. Press the (large flame) button to turn on the main burner.2.

Page 25 - Front & Top Installation

31Timer Use this setting when you come in and want to enjoy a set temperature. 1. Select either the ☼TEMP MODE or the ☽TEMP MODE by briefly pressing

Page 26

32OptionsApplianceCast StovesVentingFan (Blower)MF28ILN—Natural Gas InstallationsMF28ILP—Propane Gas InstallationsConversion KitsMFCS01—Madrona Stove

Page 27 - Owner’s Information

33Lighting InstructionsWARNING: If you do not follow these instructions exactly a ¿re or exSlosion Pay result causinJ SroSerty daPaJe Sersonal inMur

Page 28

34Wiring DiagramOptional Wall Switch Kit 1265WSKConnectorRedYellowGV60 Wiring Diagram

Page 29 - Remote Control Operation

35Venting AccessoriesAPPROVED DIRECT VENT SUPPLIERS FOR VALOR MODELS 530, 534, 535, 650, AND MF28Venting Parts Description Venting Parts Code / availa

Page 30

36Venting Accessories Venting Parts DescriptionVenting Parts Code / availability by ManufacturerSIMPSON DURA-VENTSELKIRKICC EXCEL DIRECTSECURE VENT RL

Page 31

37Warranty1. Extended Warranty CoverageFor a period of up to ten (10) years, Miles Industries Ltd., (the “Company”) or its appointed distributor will

Page 32

38Replacement Parts123456789Description Part no. Description Part no.Black Majolica Black Majolica1 Base 4000926AH 4000926MJ 6 Fret 4000935AH 4000935M

Page 33 - Lighting Instructions

39Description Part no. Description Part no.1 Log Set Complete 4001916 32Hooked Olive for Pilot Injector720A1962 Rear Log 4001932 33Olive Nut—Pilot Pip

Page 34 - Switch Kit

4Safety & Warning InformationChildren and adults should be ALERTED to the hazards of high surface temperature and should STAY AWAY to avoid burns

Page 35 - Venting Accessories

123456740Replacement Parts89101150751213141617202166182265NGLPG23242725b25a28372931363233343538394042414344454647485253515449555664636262a585759603026

Page 36

Thank You ...For purchasing a Valor by Miles Industries. Your new radiant gas heater is a technical appliance that must be installed by a qualifi ed de

Page 37 - Warranty

Tape ShutThank you for choosing a Valor ProductPostageneededWere you given all documentation and manuals for your product? YES NOMiles Industries Lt

Page 38 - Replacement Parts

5When operating your new fi replace for the fi rst time, some vapors may be released due to the burning of curing compounds used in the manufacture of t

Page 39

6Safety & Warning Information4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not a

Page 40

7Specifi cationsThis appliance is certifi ed to ANSI Z21.88-2009/CSA 2.33-2009 American National Standard / CSA Standard for Vented Gas Fireplace Heater

Page 41 - Thank You

Gas inlet position 3/8” fem.NPTxGas inlet position 3/8” fem.NPTxSupplied with top vent; fi eld convertible to rear vent8Dimensions & ClearancesInle

Page 42 - 190 - 2255 Dollarton Highway

9Dimensions & ClearancesCorner clearances Wall clearancesMantel / shelf clearancesMin. 5” between combustible wall and stoveMin. 5” between combus

Comments to this Manuals

No comments